Selecting a plug-in power supply for a 19-inch rackmount system is not an isolated component choice. The supply must match the chassis, power interface backplane, input source, output-rail requirements, cooling path, and system availability objective. A module that appears suitable by output voltage alone may still be incompatible with the backplane interface, mechanical envelope, current-sharing scheme, or thermal design.
Vector supplies plug-in power supplies for its 19-inch rackmount systems. These supplies support standard PCI output voltages of 5.0V, 3.3V, +12.0V, and -12.0V, with hot-swap operation and N+1 redundancy using internal OR-ing diodes. Selection therefore begins with the complete power architecture rather than the supply module in isolation.
Start with the chassis and power interface
The first decision is whether the rackmount system uses plug-in supplies or an embedded industrial-type power supply. Vector chassis support both approaches. The correct choice depends on the chassis configuration, the associated backplane, the available cooling path, and the system’s service requirements.
A plug-in architecture separates the supply from the primary card cage and provides a modular interface for installation, removal, and redundancy. Vector’s Power Interface Backplanes are based on PICMG 2.11 power interface requirements. They route AC or DC input to plug-in hot-swap supplies, then route the converted voltages to power lugs on the rear of the backplane for connection to the system power distribution.
This arrangement makes the backplane part of the supply-selection decision. The supply must mate with the specified interface, and the backplane must support the intended input type, output rails, current levels, sensing arrangement, and redundancy configuration. Connector compatibility should be confirmed at the system level rather than inferred from the supply’s physical dimensions.
The backplane configuration may include screw terminals, referred to as power bugs, for higher-current connections. It may also provide local or remote voltage sensing and geographical address headers for each supply. These features affect how the supply is monitored and how output regulation is managed at the point where power enters the system.

Select the AC or DC input architecture
Vector plug-in supplies are available with AC input from 90–264V. DC-input options include 36–72V with 48V nominal input, or 18–32V with 24V nominal input.
The input selection should follow the actual platform power architecture. An AC-input configuration may be appropriate where the rackmount system is connected directly to facility power. A DC-input configuration may be required where the system is integrated into a vehicle, telemetry platform, distributed power system, or other installation with an established DC bus.
The input range is only one part of the decision. The input connector, backplane routing, source protection, grounding approach, and system-level isolation must also be reviewed. A supply with the correct nominal input range is not sufficient if the chassis or power interface does not support the required connection and distribution method.
Power factor is another consideration for AC-input configurations. Vector supplies are 0.99 power factor corrected. This characteristic should be considered together with the facility input arrangement and the system’s power-management requirements.
Define the output-rail requirement
The standard PCI output voltages are:
- 5.0V
- 3.3V
- +12.0V
- -12.0V
The presence of a rail in the supply does not, by itself, establish that the rail has sufficient capacity for a particular system. The load should be evaluated rail by rail, using the requirements of the installed boards, backplane, and connected hardware.
This is especially important when the system has a mixed load profile. A design may draw most of its power from the 5.0V or 3.3V rails while imposing a different demand on the positive or negative 12V rails. The supply selection should therefore compare the required current on each rail against the corresponding supply and backplane ratings.
Vector supplies provide current sharing on the 5.0V and 3.3V outputs. In a redundant configuration, current sharing helps coordinate the contribution of multiple supplies on the supported rails. It does not remove the need to verify the load distribution, output limits, and failure-state behavior for the complete system.
Remote voltage sensing is also relevant where the distance between the supply and the load introduces a meaningful distribution path. Vector’s Power Interface Backplanes provide local or remote voltage-sensing options. The sensing method should be selected in relation to the backplane layout, power-lug arrangement, and the point at which regulation must be evaluated.
Understand N+1 redundancy as a system property
N+1 redundancy is not achieved merely by installing multiple power supplies. The complete supply, backplane, chassis, and monitoring architecture must support operation when the designated redundant capacity is unavailable.
Vector plug-in supplies support hot-swap operation with N+1 redundancy using internal OR-ing diodes. The OR-ing arrangement helps isolate a supply from the shared output path during removal or fault conditions. The system design must still verify that the remaining supplies can support the required load on every applicable output rail.
The N+1 calculation should use the actual system load, not only the combined nameplate capacity of the installed supplies. It should account for the required operating state after a supply is removed or becomes unavailable. The calculation should also be performed at the rail level, because aggregate power capacity does not establish that each individual rail remains within its rating.
Current sharing, OR-ing, supply status indication, and backplane routing should be reviewed together. The faceplate power and fault LED indicators provide local status information at the module. The system-level design should determine how those indications are used during maintenance, fault isolation, and acceptance testing.
The PICMG 2.11 specification defines electrical and mechanical interfaces and minimum requirements for modular CompactPCI pluggable power supplies and related platforms. Where a design uses a PICMG 2.11 interface, supply, backplane, and chassis compatibility should be confirmed against the applicable system documentation.
Account for load sharing and derating
A supply’s nominal output rating is only one input to the sizing process. The design should establish the expected load for normal operation, the load during high-demand operating states, and the load that remains after the designated redundant capacity is unavailable.
Derating must be treated as part of the selection criteria. The applicable supply documentation should be used to determine how output capability changes across the intended input range, ambient conditions, airflow conditions, and system configuration. The same review should be applied to the backplane power path and rear power connections.
The result should be a power architecture with defined margin at the rail level. Margin should not be assumed from unused chassis space or from the presence of an additional supply slot. It should be demonstrated through the system load calculation and verified during system testing.
Coordinate airflow and cooling
Power supplies and chassis cooling cannot be selected independently. The supply module generates heat that must be removed through the available airflow path. The chassis must provide an appropriate inlet and exhaust arrangement, and the card cage, backplane, supply position, and filler panels must not compromise that path.
The supply module's own thermal design, heat rejection, and any forced-air contribution it makes must be understood before the chassis airflow path is finalized. The chassis cooling arrangement must be evaluated alongside the supply's physical position, airflow direction, and mounting configuration. Restrictions caused by adjacent modules, card guides, panels, filters, or installation details can change the thermal condition seen by the supply and the rest of the system.
The Vector Series 443 chassis, for example, provides a 19-inch rackmount platform with provisions for plug-in power supplies and an embedded industrial-type power supply option. Its cooling configuration, card-cage arrangement, and backplane selection are part of the same system-level design decision.

What Engineers and Program Teams Should Consider
Before releasing a rackmount power configuration, review the following items as a single interface definition:
- Chassis compatibility, supply position, module height, and mechanical retention
- AC or DC input selection and the available system power source
- Input and output connector compatibility with the selected backplane
- Required 5.0V, 3.3V, +12.0V, and -12.0V rail currents
- Current-sharing behavior on the 5.0V and 3.3V outputs
- N+1 operation after the designated redundant capacity is unavailable
- OR-ing behavior during hot-swap removal, insertion, or fault conditions
- Local or remote voltage sensing requirements
- Backplane power-lug and power-bug connections
- Geographical address requirements for individual supplies
- Airflow direction, cooling capacity, and supply fan interaction
- Derating across the intended input and environmental operating conditions
- Faceplate power and fault indication requirements
- PICMG 2.11 power interface compatibility where applicable
- Required cULus, TUV, and CE markings for the program

The practical principle is straightforward: select the power supply as part of the rackmount system’s power and thermal architecture. Input range, output rails, connector interfaces, current sharing, N+1 redundancy, sensing, cooling, and backplane distribution must agree before the configuration is considered complete.
Vector supplies are engineered and manufactured in the USA, with over 70 years of manufacturing experience. Vector is ISO 9001 and AS9100 certified and ITAR registered. For mission-critical rackmount systems, those production controls support the broader requirement for configuration control, traceability, and consistent integration across the chassis, backplane, power supplies, and cooling system.
Technical references
- Vector Power Interface Backplanes, P47
- Vector plug-in power supplies
- Vector Series 443 chassis
- PICMG 2.11 CompactPCI Power Interface Specification